Specifications

24
Location and Function of Parts
9
VISCA RS-232C IN connector
Connect to the RM-BR300 Remote Control Unit.
When you join multiple cameras, connect it to
the VISCA RS-232C OUT connector of the
previous camera in the daisy chain.
VISCA RS-232C OUT connector
When you join multiple cameras, connect it to
the VISCA RS-232C IN connector of the next
camera in the daisy chain.
CAMERA connector
8
Please note that the same camera address
cannot be assigned to two or more different
cameras.
Note
Switch 6 is not used.
Camera
0 1 2 3 4 5 6 7
address
Switch 3
OFF ON OFF ON OFF ON OFF ON
Switch 4
OFF OFF ON ON OFF OFF ON ON
Switch 5
OFF OFF OFF OFF ON ON ON ON
10
11
5.3 Optical Multiplex Cards and Optional Video Cards
The following provides information on the location and function of optical multiplex card parts and
optional video cards and optional video cards. The BRC Series allows you to choose from a wide range of
optional video cards. This versatility enables you to create flexible analog and digital system configurations.
5.3.1
BRBK-H700 HD Optical
Multiplex Card
1
AUDIO IN L/R jacks (phono-type)
Input an audio signal (stereo) that is output
from the AUDIO OUT jacks on the BRU-H700 HD
Optical Multiplex Unit via an optical fiber cable.
The audio input on this board accepts audio
line signals only. When you input audio signals
from a microphone or similar device, it should
be connected with a microphone amplifier so
that audio signals with an
appropriate audio level can be input.
Optical connector
2
1 2
5.2.3 BRU-300/300P SD Optical
Multiplex Unit for use with the
BRC-300/300P
Rear
IN EXT SYNC OUT
S VIDEO
VISCA RS-232C CAMERA
~
AC IN
IN OUT
VISCA RS-422
FUNCTION
1
6
1 2
3 4 5 6 7 8 9 10 11
Card slot
AC IN connector
EXT SYNC IN connector
EXT SYNC OUT connector
Composite video output connector
S-VIDEO connector
VISCA RS-422 connector
VISCA FUNCTION switches
Switch 1
(RS-232C/RS-422 selector)
Set to ON for RS-422, or OFF for RS-232C.
Switch 2 (
Communication baud rate selector
)
Set to ON for 38400 bps, or OFF for 9600 bps.
1
2
3
4
5
6
Switches 3 to 5 (Camera address selectors)
Set the address of the camera. Normally set to
0. With this setting, addresses are assigned to
the cameras automatically in the connected
order by pressing the POWER button while
holding down the RESET button on the
RM-BR300 Remote Control Unit. You can assign
the camera address, 1 to 7, manually by setting
these selectors as follows:
7