Specifications
23
Location and Function of Parts
5.2.2
BRU-H700 HD Optical Multiplex
Unit for use with the BRC-H700
and BRC-Z700
Rear
IN EXT SYNC OUT
IN
VISCA RS-232C
OUT
CAMERA
~AC IN
VISCA RS-422
AUDIO OUT
L
R
FUNCTION
1 6
RGB/COMPONENT
1 2 3
4 5 6 7 8 9 10 11
1
Card slot
AUDIO OUT L/R jacks
Loop through output of the audio line signal
input from the AUDIO IN jacks on the BRBK-H700
HD Optical Multiplex Card or BRBK-MF1 HD
Optical Multiplex Card inserted into the camera
via an optical fiber cable.
~
AC IN connector
CAMERA connector
EXT SYNC IN connector
EXT SYNC OUT connector
RGB/COMPONENT connector
Pin No. Signal Pin No. Signal
1 Pr/R 9 NC
2 Y/G 10 GND
3 Pb/B 11 GND
4 GND 12 NC
5 GND 13 HD-OUT
6 GND 14 Tri-level Sync/Bi-level VD
7 GND 15 NC
8 GND
VISCA RS-232C IN connector
Connect to the RM-BR300 Remote Control Unit.
When you join multiple cameras, connect it to
the VISCA RS-232C OUT connector of the previ-
ous camera in the daisy chain.
VISCA RS-232C OUT connector
When you join multiple cameras, connect it to
the VISCA RS-232C IN connector of the next
camera in the daisy chain.
VISCA RS-422 connector
2
3
4
5
6
7
VISCA FUNCTION switches
Switch 1
(RS-232C/RS-422 selector)
Set to ON for RS-422, or OFF for RS-232C.
Switch 2 (
Communication baud rate selector
)
Set to ON for 38400 bps, or OFF for 9600 bps.
Switches 3 to 5 (Camera address selectors)
Set the address of the camera. Normally set to
0. With this setting, addresses are assigned to
the cameras automatically in the connected
order by pressing the POWER button while
holding down the RESET button on the
RM-BR300 Remote Control Unit. You can assign
the camera address, 1 to 7, manually by setting
these selectors as follows:
11
Please note that the same camera address
cannot be assigned to two or more different
cameras.
Note
Switch 6 (
59.94i/50i signal format selector
)
Set to ON for output of 50i signal format, or OFF
for output of 59.94i signal format.
Please further note that you must set the switches
before you turn on power to the multiplex unit.
Note
Camera
0 1 2 3 4 5 6 7
address
Switch 3
OFF ON OFF ON OFF ON OFF ON
Switch 4
OFF OFF ON ON OFF OFF ON ON
Switch 5
OFF OFF OFF OFF ON ON ON ON
8
9
10