Specifications

22
Location and Function of Parts
5
VISCA RS-232C IN connector
Connect to the RM-BR300 Remote Control Unit
(not supplied). When you connect multiple
cameras, connect it to the VISCA RS-232C OUT
connector of the previous camera in a daisy-
chain connection.
6
VISCA RS-232C OUT connector
When you connect multiple cameras, connect
it to the VISCA RS-232C IN connector of the next
camera in a daisy-chain connection.
7
VISCA RS-422 connector
8
AUDIO OUT L/R jacks
Loop through output of the audio line signal
input from the AUDIO IN jacks on the BRBK-SF1
HD Optical Multiplex Card inserted into the
camera via the Optical Fiber Cable.
9
VISCA FUNCTION switches
These switches are used for the VISCA
communication settings.
Switch 1 (RS-232C/RS-422 selector)
Set to ON for RS-422, or OFF for RS-232C.
Switch 2 (Communication baud rate
selector)
Set to ON for 38,400 bps, or OFF for 9,600 bps.
Switches 3 to 5 (Camera address
selectors)
Set the address of the camera.
Normally set to “0”. With this setting, addresses
are assigned to the cameras automatically in
the connected order by pressing the POWER
button while holding down the RESET button on
the RM-BR300 Remote Control Unit (not
supplied).
You can assign the camera address “1” to “7’
manually by setting these selectors as follows:
Camera
address
0 1 2 3 4 5 6 7
Switch 3
OFF ON OFF ON OFF ON OFF ON
Switch 4
OFF OFF ON ON OFF OFF ON ON
Switch 5
OFF OFF OFF OFF ON ON ON ON
Note
Please note that the same camera address
cannot be assigned to two or more different
cameras.
Switch 6 (59.94/50 signal format selector)
Set to ON for output of 50 signal format, or OFF
for output of 59.94 signal format.
Switches 7 to 10
Not used. Set them to OFF.
Note
Please further note that you must set the switches
before you turn on power to the multiplex unit.
10
DC 12 V connector
11
Card slot