Location and Function of Parts
Bottom
15 16 17
Ceiling bracket mounting screw holes
Tripod screw holes (1/4-20UNC)
BOTTOM switches
4
Switch 1, 2, 3 (Camera address selectors)
Set the address of the camera.
Normally set to “0”. With this setting, addresses
are assigned to the cameras automatically in
the connected order by pressing the POWER
button while holding down the RESET button on
the RM-BR300 Remote Control Unit.
You can assign the camera address “1” to “7”
manually by setting these selectors as follows:
Camera
address
0 1 2 3 4 5 6 7
Switch 1
OFF ON OFF ON OFF ON OFF ON
Switch 2
OFF OFF ON ON OFF OFF ON ON
Switch 3
OFF OFF OFF OFF ON ON ON ON
5
Switch 4 (Infrared signal output switch)
Set to ON to enable an infrared signal output,
or OFF to disable the output.
Note
Please note that the same camera address
cannot be assigned to two or more different
cameras. Furthermore, you must set the switches
before you turn on camera power.
15
16
17
Setting of the BOTTOM switches
O
N
1
2
3
4
O
N
1
2
3
4
1
2
3
4
5
1
Switch 1, 2 (signal format selector)
Depending on the setting of the Switch 1, 2, the
signal format is changed as follows:
Signal
format
1080/
59.94i
1080/50i
720/
59.94p
720/50p
Switch 1 OFF ON OFF ON
Switch 2 OFF OFF ON ON
2
Switch 3 (RS-232C/RS-422 selector)
Set to ON for RS-422, or OFF for RS-232C.
3
Switch 4 (Communication baud rate
selector)
Set to ON for 38,400 bps, or OFF for 9,600 bps.