User Manual
Confidential
USERS MANUAL
15(41)
Document number Revision
4/198 17-LXE 108 566 Uen PA6
[VCC_MAIN supply is the primary CM52 power supply]
Parameter Minimum
Value
Typical
Value
Maximum
Value
Units
Input Voltage 4.5 5 5.5 V
In AMPS Call on Power Level 0
(Power Class I)
0.59 0.75 A
In AMPS Call on Power Level 2 0.83 1.0 A
In CDMA call-Cellular Mode 0.67 0.90 A
In CDMA call-PCS Mode 0.72 0.95 A
CDMA burst duration for Network
update
1.2 S
Standby/Idle Current Draw in
Slotted Mode (CDMA)
1.28 sec slot 9.6 mA
2.56 sec slot 7.2 mA
5.12 sec slot 4.5 mA
Stand-by/Idle mode (AMPS) 45 mA
Powered Down Current Draw 1
µA
Inrush Current (on wake up) 2.2 A
Duration of Inrush (on wake-up) 150
µ s
Inrush Current (contact) 2.0 A
Duration of Inrush (contact) 50
µ s
Table 8: VCC_MAIN Supply Power Consumption
Notes
1. The typical current measurements noted in CDMA mode are with the following
settings:
a. CDMA-Cellular (800MHz): Band = IS-2000, Cell-Power = -104dBm,
Channel Number 358
b. CDMA-PCS (1900MHz): Band = IS-2000, Cell-Power = -104dBm,
Channel Number 563
Maximum Slot Cycle Index for both 800MHz and 1900MHz modes = 1
2. The inrush current measurements noted here are with respect to the stand alone
CM52 module at room temperature, the results might vary when the CM52 is used
in the Customer Application.
3. Measurements are based on worst case scenario—CM52 with 3W option. Values
for CM52 with no 3W option could be marginally lower.