User Manual

Confidential
USERS MANUAL
14(41)
Document number Revision
4/198 17-LXE 108 566 Uen PA6
[VCC_AUX power supply supports the 3W mode AMPS circuitry]
Parameter Minimum
Value
Typical
Value
Maximum
Value
Units
Input Voltage 11 13.8 16.6 V
In a Call on Power Level 0
(Power Class I)
0.88 1.3 A
In a Call on Power Level 2 3.5 4.5 mA
AMPS Burst Duration for network
update
0.16 s
Stand-by/Idle mode (RX ON) 0.5
µ
A
Powered Down Current Draw 1
µ
A
Inrush Current (Entering PL0) 16 A
Duration of Inrush (Entering PL0) 40
µ
s
Inrush Current (contact) 28 A
Duration of Inrush (contact) 40
µ s
Table 7: VCC_AUX Supply Power Consumption
Note: The typical values observed in AMPS call are made with voice channel set at
358.