User's Manual
LZT 123 1834 57
MSB
MSB
LSB
LSB
LSB
LSB
MSB
MSB
Frame nFrame n-1 Frame n+1
SSPCLK
SSPFS
SSPDFM
SSPDTM
MSB
MSB
LSB
LSB
LSB
LSB
MSB
MSB
Frame nFrame n-1 Frame n+1
SSPCLK
SSPFS
SSPDFM
SSPDTM
Figure 5.10-3 PCM Frame format for a continuous transfer
The PCM interface has a Slave mode, however the allocated DSP buffer size limits the
maximum data rate available. A separate Application Note describing slave mode
implementation can be obtained from Sony Ericsson through Customer Support.
5.11 Serial Data Interfaces
The serial channels consist of two UARTs and a USB port. These provide
communication links to the application or accessory units.
The serial channels can be used in differing configurations, depending upon the users
requirements and application. However, the common configuration options are
described:
• UART1 has full RS-232 functionality and is used for all on- and off –line
communication (modem sleep & wake functional control is an integral component
of this interface). Its intended use is that of the primary command (AT) interface.
• UART3 behaves as a general-purpose serial data link. It can be used for data
logging and de-bugging purposes. A GPS device can be used with UART3 as part
of an embedded application.
• The USB port provides a convenient general purpose peripheral (slave) port for use
with host devices which have USB controllers.