User Manual
11. TECHNICAL DATA
53
LZ T 123 7605 P1C
Talk Mode: The module is switched ON and a voice/data call is in
progress.
The power consumption during transmission in Talk Mode is measured at
maximum transmit power.
The power consumption in Standby Mode is measured at the maximum
paging rate (Paging Rate 2).
Current Consumption with external +4.8V Supply Active
For the following calculations it was assumed that the external +4.8V load
is 70mA.
These tables do not include the power consumption associated with any
drive current supplied via further Control Terminal outputs, e.g. OUT-1
or OUT-2.
Supply Voltage 5V 12V 32V
Power Down Mode:
Av Max Av Max Av Max
5 15 5 15 20 50 mA
Standby Mode (typical):
Frequency AvMax AvMax AvMax
850/900 MHz 112 196 45 79 19 33 mA
1900/1800 MHz 112 206 45 81 19 32 mA
Talk Mode (typical):
Frequency AvMax AvMax AvMax
850/900 MHz 306 1316 126 556 53 213 mA
1900/1800 MHz 256 1046 106 386 43 153 mA