User Manual
11. TECHNICAL DATA
52
LZ T 123 7605 P1C
Environmental specifications
Current Consumption in Standard Operation
Power Down Mode: DC power is applied but the Control Terminal is
switched OFF.
Standby Mode: The module is switched ON and attached on to the
network. No call in progress.
Operating temperature
range
–30°C to +75°C
Storage temperature
range
–40°C to +85°C
Relative humidity 5 to 95%, non-condensing
Stationary vibration,
sinusoidal
Displacement: 7.5mm
Acceleration amplitude: 20m/s² and 40m/s²
Frequency range: 2 to 8Hz, 8 to 200Hz, 200 to
500Hz
Stationary vibration,
random
Acceleration spectral density (m²/s²):
0.96, 2.88, 0.96
Frequency range:
5 to10Hz, 10 to 200Hz, 200 to 500Hz, 60min/axis
Non-stationary vibration,
including shock
Shock response spectrum I, peak acceleration:
3 shocks in each axis and direction;
300m/s², 11ms
Shock response spectrum II, peak acceleration:
3 shocks in each axis and direction;
1000m/s², 6ms
Bump Acceleration: 250m/s²
Free fall transportation 1.2m
Rolling pitching
transportation
Angle: ±35degrees; period: 8s
Static load 10kPa
Low air pressure/high air
pressure
70kPa/106kPa
Supply Voltage 5V 12V 32V
Power Down Mode:
Av Max Av Max Av Max
5 15 5 15 20 50
mA
Standby Mode (typical):
Frequency Av Max Av Max Av Max
850/900 MHz 26 110 9 43 6 20 mA
1900/1800 MHz 26 120 9 45 6 19 mA
Talk Mode (typical):
Frequency Av Max Av Max Av Max
850/900 MHz 220 1230 90 520 40 200 mA
1900/1800 MHz 170 960 70 350 30 140 mA