Note: DSR is considered permanently ready for a module, therefore
any DGND connection may be taken as DSR functionality.
3.10.4 UART 2 - TD2, RD2
The UART 2 consists of a full duplex serial communication. This
involves the transmission and reception lines.
The communication port shall work in one mode: Operation and
Maintenance mode.
Operation and Maintenance mode shall work in addition with
SERVICE signal. On switching the module on, if SERVICE signal is
active then two events can happen. If no data is sent to the module,
then the logger is activated. Otherwise, the module shall be ready to
be reprogrammed.
Timing and Electrical signals characteristics equal to UART 1 TD and
RD, except for maximum baud rate that could be increased to 921
KBPS.
Transmitted Data 2 (TD2)
TD2 is input (to the module) used by the application system to send
data on the UART 2 to the module.
The electrical characteristics shall be the same as TD.
Received Data 2 (RD2)
RD2 is an output used to send data on the UART 2 to the application
system.
The electrical characteristics shall be the same as RD.
3.10.5 UART 3 - TD3, RD3
The UART 3 consists of a full duplex serial communication. This
involves the transmission and reception lines.
Timing and electrical signals characteristics equal to UART 1 TD and
RD.
Transmitted Data 3 (TD3)
TD3 is input (to the module) used by the application system to send
data on the UART 3 to the module.
The electrical characteristics shall be the same as TD.