User Manual
GM47/GM48 INTEGRATOR’S MANUAL
212
LZT 123 7263 R1A
There are four presentation format modes (Display, Compact, Verbose,
and Reduced Display) and two response types (one shot response or
continuous unsolicited responses).
The purpose of the presentation format mode Display is to display the
data in a readable form, including headers and line breaks
(<CR><LF>). This format is, however, not well suited for machine
decoding. The formats Verbose, Compact and Reduced Display do not
have headers or line breaks. Verbose mode displays more parameters
than the compact mode.
The response types give the user the choice of one a shot information or
an unsolicited response with <m> seconds between each response.
Examples
AT*E2EMM=1
*E2EMM:<CR><LF>
Serving Cell<CR><LF>
MCC,MNC,LAC,CellID,BSIC,Ch[,RxL,C1,C2][,RxLFull,RxLSub,Rx
QFull,RxQSub,TA,TN]<CR><LF>
<mcc>,<mnc>,<lac>,<ci>,<bsic>,<ch>[,<rxl>,<c1>,<c2>][,<rxlFull>,
<rxlSub>,<rxqfull>,<rxqsub>,<ta>,<tn>]<CR><LF>
NeighBours Cells<CR><LF>
MCC,MNC,LAC,CellID,BSIC,Ch,RxL[,C1,C2]<CR><LF>
<mcc>,<mnc>,<lac>,<ci>,<bsic>,<ch>,<rxl>[,<c1>,<c2>]<CR><LF>
<mcc>,<mnc>,<lac>,<ci>,<bsic>,<ch>,<rxl>[,<c1>,<c2>]<CR><LF>
…
<mcc>,<mnc>,<lac>,<ci>,<bsic>,<ch>,<rxl>[,<c1>,<c2>]<CR><LF>
OK
AT*E2EMM=3
*E2EMM: <servcell mcc>,<servcell mnc>,<servcell ci>,<servcell
bsic>,<servcell ch>[,<servcell rxl>][,<servcell rxlSub>,<servcell
rxqsub>,<servcell ta>],<neighborcell1 mcc>,<neighborcell1
mnc>,<neighborcell1 ci>,<neighborcell1 bsic>,<neighborcell1
ch>,<neighborcell1 rxl>,<neighborcell2 mcc>,<neighborcell2
mnc>,<neighborcell2 ci>,<neighborcell2 bsic>,<neighborcell2
ch>,<neighborcell2 rxl>,
…
<neighborcelln mcc>,<neighborcellnmnc>,<neighborcellnci>,
<neighborcelln bsic>,<neighborcelln ch>,<neighborcelln
rxl><CR><LF>
OK
AT*E2EMM=5
*E2EMM: <servcell mcc>,<servcell mnc>,<servcell lac>,<servcell
ci>,<servcell bsic>,<servcell ch>[,<servcell rxl>,<servcell
C1>,<servcell C2>][,<servcell rxlFull>,<servcell rxlSub>,<servcell
rxqfull>,<servcell rxqsub>,<servcell tn>,<servcell ta>],