4.12 AT*ERIL Ericsson Ring Level Set
Used to set the volume for the ring signals used for incoming voice,
Line 1, Line 2, fax and data calls. The parameter <place> controls the
ring level set for different types of modes. The signal volume is
specified as “step”, with an increasing volume for each signal, or as a
selected level.
Line 1 is the default for <call type> if the parameter is not given.
Description Command Possible Responses
Sets ring volume for the
ring signals used for
incoming voice (L1
and L2), fax and data
calls
AT*ERIL=<volume>[,<c
all type>
[,<place>]]
•+CMEERROR:<err>
•OK
•ERROR
Read the settings of
volume for the ring
signals
AT*ERIL? •*ERIL:
<volume1>[,<call
type1> [,<place1>
[<CR><LF>…*ERIL:
<volume n>[, <call
type n> [,<place
n>]]]]]
•+CMEERROR:<err>
•OK
•ERROR
Test if the command is
supported
AT*ERIL=? •*ERIL:(listof
supported
<volume>s)[,(list of
supported <call
type>s)
[,(list of supported
<place>s)]]
•+CMEERROR:<err>
•OK
•ERROR
<volume> Description
0 Off
1-6 Volume setting, not increasing ring
129-134 Volume setting, increasing ring
<calltype> Description
1 Line 1
2 Line 2
3 Fax
4 Data
5 Alarm. Not supported