Manual

4.7 DescriptionofControls 4 THE OXFORD DENOISER
4.7.3 De-HisserPanel
Select the frequency above
which the De-Hisser is active
Enable and Disable the
De-Hisser processing
Adjust the reduction
amount in dBs
4.7.4 DetectPanel
This is the most critical control to get right.
It sets the level of the threshold about which
noise reduction takes place.
Frequency components below the threshold
are attenuated, whereas components above
the threshold are left alone.
Adjust the ‘peakiness’ of the noise profile.
In some situations this can help to remove
musical noise.
AUTO — Enables automatic updating of
noise profile and the noise profile level
relative
to the input signal.
FREEZE — Once you have obtained a good
profile, this button will freeze the profile to
prevent it updating.
MANUAL — In this mode, the profile is
forced flat. You can then use the Colour, Air
or bias controls to modify the shape of the
profile.
Modify the LF shape of the noise profile. Modify the HF shape of the noise profile.
www.sonnox.com 41 Gotocontents