33
HF Q — Controls HF Q from 0.5 to 16.
HF FREQ — Controls the HF section frequency from 500Hz to 20KHz.
HF GAIN — Controls LF gains between -20dB and +20dB.
LF SHELF and HF SHELF — Individually select shelving responses for LF and HF
sections.
INPUT GAIN* — Adjusts the input level to the EQ section from –20dB to 0dB to avoid EQ
clipping when in boost settings.
EQ S-C — Routes the EQ processing into the sidechain.
EQ SIGNAL — Routes the EQ processing into the main signal path.
(SC-EQ) IN — Toggles the sidechain EQ in and out for comparison purposes.
* Note that the EQ gain control is needed to avoid signal clipping when the EQ is used in
the signal path with boost settings. Therefore changes to the EQ gain will modify effective
thresholds in the dynamics section. However, due to internal overload margins within the
dynamics, it is legitimately possible to boost EQ signal levels up to +24dBr when used in
the sidechain, even though these signals would cause overloads if the EQ were routed to
the main signal path.