2.3.8  Compressor Timing Laws 
The Oxford compressor offers three compression types designated NORMAL, CLASSIC 
and LINEAR, selected sequentially via a button in the centre of the Dynamics display. The 
time constant laws employed define the major difference between these types. 
The Oxford Dynamics uses both Exponential dB/time and Linear dB/time laws as illustrated 
below: 
Exponential/dB curve used in Normal and Classic types 
Linear/dB curve 
The Oxford Dynamics time settings are displayed as real time constants when in exponential 
mode. In linear mode the display is scaled to correspond to the time required for a 10dB 
change of level. This provides a degree of parity between the perceived timings of the two 
laws, which facilitates comparison and selection between compression types. These two laws 