The Sonnox Fraunhofer Pro-Codec plug-in contains internal data not normally found in a
plug-in, such as lenames and folder paths. This has prompted the adoption of a slightly
different preset model in order to allow the creation and utilization of independent
libraries of data presets.
6.1.1 Internal Data Rules
The following special data have special rules applied to them:
The Export Settings data (the Custom String, filename attributes and Output Path)
The Master Record button and five Record ARM buttons
Unless detailed otherwise, all other data are always returned in any form of preset
load.
Rule 1: Project / Session loads (and host preset loads)
Will load all data as it was saved, including all the Special data above.
Rule 2: Onboard Preset Manager (PM) preset loads (and PM copy/pastes, +/-)
Will not load any of the special data listed above.
To be more specific:
Output folder
Remains as set.
Output filename elements
Remains as set.
Custom String
Reset to the default ‘MyTrack’.
TRIM dB
All five are reset to 0 dB.
Record ARM
Master Record and all ve codec record arm buttons are reset to off.