Configuration Tool and Utilities Operation Manual Instruction Manual

23
1.4 Enclosure (SES) Health Monitoring
Many Fusion drive enclosures contain a SCSI enclosure processor
which tracks enclosure health status, drive identication and drive
fault identication. The ATTO Conguration Tool recognizes drive
enclosures that provide SCSI Enclosure Services (SES).
Use the ATTO Conguration Tool to gather the health status of
the enclosures power supplies and fans. If the status of either of
these sub-systems indicates a failure, the controller reports the
problem. The Configuration Tool shows the status of selected SES
devices and reports the specic health of each sub-system.
SES Status Checking
1. Select the Fusion drive enclosure from the Device Listing
tree in the Configuration Tool. See Figure 19 on page 24.
2. Select the SES tab at the top of the right pane.
3. View the overall status of each component across the top of
the right pane. See Figure 20 on page 24.
Note: Depending on the Fusion storage system used, some features may
not be fully supported.
4. Select a specic sub-system (power supply or fans) and view
the status of the reporting sub-system.
Support Note: This feature does not work with Fusion
D400RAID, Fusion D800RAID, nor Fusion R800RAID
storage systems.