Cut Sheet

General specification
Grid integration AC coupled
Applications On-grid: self-consumption,
backup power
Transfer switch Automatic, integrated
Backup capacity
2 kilowatt-hours per battery
module, up to 20kWh
Listed and recognized
components
Certified to UL 9540, UL 1741
(inverter) and UL 1973 (batteries)
standards**
Warranty*
15 year or 15,000 cycle system warranty
- includes inverter,
battery modules,
cabinet and components
Inverter eciency
92.5% CEC weighted, 95.0% peak
Roundtrip eiciency %
(Grid<>Battery)
>= 86%
Comm. ports Serial, Ethernet
Communication and
control standards
Control4 and Crestron drivers included
EMC / EMI protection FCC Part 15B
Transfer switch specification
Current rating
200 amps switching
and overcurrent protection
Voltage rating
120/240 VAC
Certification
UL Recognized Component
Transfer Time
< 70 ms
Nominal frequency
60 Hz
Battery Specification
DC battery input voltage 48–56 VDC
Max charge current
40 A per module
Nominal charge current
30 A per module
Cell discharge
95% DoD
Overcharge Protection
Fuse protection
AC specification
Max AC grid current
Nominal frequency
60 Hz
Adjustable frequency range
+/- 0.7 Hz from nominal
Metering capability
Power meter for load and
PV production (not revenue grade)
Tare losses (W)
60 watts
Transient protection
IEEE C62.41 Class B
Measurements
We reserve the right to make technical changes. The values, outputs, other technical data, images, and diagrams in this prospectus and in
data sheets, advertisements, and other promotional documents are approximate guidelines in all cases where they have not been identified as
binding.
*Please observe our applicable warranty conditions.
**The sonnenBatterie system is certified by ETL to UL 9540 standards and employs UL 1973 Recognized Batteries (Murata/Sony UL file
MH48699/model number IJ1001M) and an inverter certifiedby ETL to UL 1741 standards.
info@sonnen-batterie.com · www.sonnen-batterie.com
sonnen Inc.
2048 Weems Rd, Building C
Tucker, GA 30084
Phone: +1 (310) 853-2404
14.17
74.11
25.59
AC grid voltage
120/240 volts
Ventilation
Forced Air
Temperature Range
41 °F - 113 °F
Indoor - NEMA 12
Outdoor NEMA 3R
ecoLinx 10 / 12 / 14 / 16
14.17
82.11
25.59
ecoLinx 18 / 20
30 amps