Global User Guide

Table Of Contents
50
REGULATORY INFORMATION - USA MARKET
INTRINSICALLY SAFE (IS)
PART I: EX MARKING
ATEX Sira 18ATEX2077X
II 3 G Ex ic IIC T4 Gc IP64
II 3 D Ex ic IIIC T135 Dc IP64
IECEx IECEx CSA 18.0030X
Ex ic IIC T4 Gc IP64
Ex ic IIIC T135 Dc IP64
PART II: APPLICABLE ENVIRONMENT
The equipment may be used in zones 2 with amma-
ble gases and vapours with apparatus groups IIC and
with temperature classes T4.
The equipment may be used in zones 22 with
ammable dusts, bers and yings in groups IIC, with
a layer auto-ignition temperature of not less than 75
K above the maximum surface temperature marked
in the dust coding.
PART III: SPECIAL CONDITIONS OF USE
If the equipment is likely to come into contact with
aggressive substances, e.g. acidic liquids or gases
that may attack metals or solvents that may affect
polymeric materials, then it is the responsibility of the
user to take suitable precautions that prevent it from
being adversely affected thus ensuring that the type
of protection is not compromised.
The certicate number has an ‘X’ sufx which
indicates that special conditions of installation
and use apply. Those installing or inspecting this
equipment must have access to the contents of the
certicate or these instructions. The conditions listed
in the certicate are reproduced below:
The equipment shall only be charged when in the
non-hazardous area using a charger specically
supplied for use with the unit.
Using the equipment shall prevent expose to the
daylight or light.
XP8800 was tested in accordance low risk of
mechanical danger, hence to avoid mechanical
impact in normal use.