Manual

Table Of Contents
Reference Monitors User Handbook
51
4
SERIAL INTERFACE
COMMANDS & RESPONSES
SERIAL INTERFACE COMMANDS & RESPONSES
Command Description Response
OPT:2,xx Source autodetection for RM-2S10 (see page 6): ACK:
Where: x = 00 selects normal operation (default setting)
x = 01 enables source autoselection (hex values 01 to FF
accepted and have same eect as 01).
The SRQ: query will correctly report the bank currently in use.
The UID: query will report a single bank of 10 sources rather than
two when autoselect is enabled.
SER: - Serial Number request SER:nnnnnn
SRQ: - Status request SRQ:BxLyRz
Where: x = current bank number (1…n).
y = current source number for LH speaker (1…n).
z = current source number for RH speaker (1…n).
SS1:nn - Set Left-hand Source ACK:
nn = Source number, starting with 01.
SS2:nn - Set Right-hand Source ACK:
nn = Source number, starting with 01.
UID:* - Unit ID Request UID:RM4:V11yyyy
or UID:RM-2S4-xxxxxx
or UID:RM-2S10-xxxxxx
or UID:RM-4C8-xxxxxx
or UID:RM4/A (bootloader)
Where: x = number of sources available in each of banks 1-6
y = dependent on Banks tted.
VER:* - Firmware Version Request VER:n.nn
or BOOT:n.nn (bootloader)
* = these commands also valid in Bootloader mode.
Error Messages
ERR:01 - returned if Command Not Found.
ERR:02 - returned if Missing Parameter.
ERR:04 - returned if Parameter out of range.
ERR:08 - returned if Checksum Error occurs during reprogramming.
Firmware Updates
The internal rmware of the Reference Monitors can be updated to take advantage of
newly added features. It is recommended that this be done using the Sonifex SCi remote
control package, but it may also be done using the command protocol provided and the
“Send Text File” (or similar) facility in text-based terminal programs such as Hyperterminal.
When prompted for a lename, locate and select the .DWN le provided with the
rmware update.