Manual

Table Of Contents
36
Reference Monitors User Handbook
REFERENCE MONITORS RM-4C8
REFERENCE MONITORS RM-4C8
2
Rear Panel Connections & Operation
Fig 2-13: RM-4C8 Rear
Mains Power
Power is applied to the unit via a standard three-pin IEC male socket. Mains voltages
between 85 and 264V AC and frequencies between 47 and 63Hz are accepted without
adjustment.
The Earth pin MUST be connected to ensure safety.
Digital Input Termination
Switchable termination is provided to allow the RM-4C8 inputs to be bridged across
an existing AES/EBU connection without double-termination, but this should only be
attempted with the terminating equipment mounted adjacent to the RM-4C8 and with
connections kept as short as possible.
It is strongly recommended that the digital input termination is set to ON at all times.
Failure to do so may result in unreliable reception of digital input signals and/or crosstalk
between Sources.
110 ohm input termination for the AES/EBU digital inputs is controlled by the settings of
switches 1, 2, 11 and 12 on Block 2 of the conguration switches (see Fig 2-6: The RM-4C8
DIPSwitch Settings), as follows:
SW1: When set to ON, digital input A1/2 is terminated with 110Ω.
SW2: When set to ON, digital input A3/4 is terminated with 110Ω.
SW11: When set to ON, digital input B1/2 is terminated with 110Ω.
SW12: When set to ON, digital input B3/4 is terminated with 110Ω.
Input Gain Adjustment
For both analogue and digital Sources the default input gain is zero, i.e. an input of 0dBu
results in a reading of 0dBu on the meters. However, to accommodate lower level sources
it is possible to introduce extra global input gain in 6dB steps. This gain applies to all
inputs and is controlled by the settings of switches 6 and 7 on the right-hand block of
conguration switches (found on the underside of the unit), according to the following
table. Power should be removed from the unit while making changes to the conguration
switches and reapplied once the changes are complete.
Input Gain Maximum Signal Level
(Analogue Sources)
Maximum Signal Level
(Digital Sources)
SW6 SW7
0dB +18dBu 0dBFS OFF OFF
+6dB +12dBu -6dBFS ON OFF
+12dB +6dBu -12dBFS OFF ON
+18dB 0dBu -18dBFS ON ON