Manual

Table Of Contents
28
Reference Monitors User Handbook
REFERENCE MONITORS RM-4C8
REFERENCE MONITORS RM-4C8
2
Front Panel Indicators & Controls
Fig 2-3: RM-4C8 Front Panel Controls
Power LED
The POWER LED illuminates whilst internal power is present within the unit. If this indicator
is not on, the most likely reason is simply the absence of mains power, but under fault
conditions it may also indicate a ruptured mains fuse or a problem with the internal power
supply module.
Rotary Source Selectors
Fig 2-4: RM-4C8 Rotary Source Selectors
The two rotary Source selectors determine which of the four audio inputs in the currently
selected Bank is routed to each loudspeaker. To increment the Source number, the left-
hand selector should be turned anticlockwise and the right-hand selector clockwise;
rotation in the opposite direction decrements the Source number. The currently selected
Sources are indicated by illumination of the corresponding Source LEDs.
The currently selected Sources may also be changed via the remote control ports, using the
Sonifex SCi software and such changes will also be reected by the Source LEDs.
The Source selectors are endless rotary encoders; further rotation once the lowest/highest
Source has been selected will be ignored. If the currently selected Bank contains fewer
than four Sources, it will not be possible to select unimplemented Sources.
When mains power is removed, the currently selected Sources are stored in non-volatile
memory and recalled instantly once power is restored.