REFERENCE MONITORS RM-2S4 & RM-2S10
REFERENCE MONITORS RM-2S4 & RM-2S10
1
Fig 1-9: RM-2S4 & RM-2S10 DIPSwitch Settings
Note that power should be removed from the unit while making changes to the
conguration switches and reapplied once the changes are complete.
Meter
Characteristic
Scale Range*
Amber
Section
Starts at*
Red
Section
Starts at*
SW8 SW9 SW10
Dual PPM + VU -13 to +13dBu 0dBu +8dBu OFF OFF OFF
BBC PPM or EBU
PPM**
-13 to +13dBu 0dBu +8dBu ON OFF OFF
Nordic PPM -40 to +12dBu 0dBu +8dBu OFF ON OFF
AES Digital PPM -52 to 0dBFS -3dBFS 0dBFS ON ON OFF
DIN PPM -54 to +5dBu 0dBu +4dBu OFF OFF ON
Standard VU -24 to +3VU -4VU 0VU ON OFF ON
Extended VU -59 to +15VU -4VU 0VU OFF ON ON
Currently unused – do not select ON ON ON
* With 0dB of input gain selected.
** May be BBC or EBU PPM depending on the choice of scale plate.