The available settings for output 3, configured using switches Sw9 to Sw12, are
detailed below:
Setting
No
Sw9 Sw10 Sw11 Sw12 Description
1 Off Off Off Off Flash Output 3 when telephone rings
Output 3 On when telephone is off-hook
2 On Off Off Off Output 3 On when telephone is off-hook
3 Off On Off Off Flash Output 3 when telephone rings
4 On On Off Off Output 3 On when Remote 1 asserted
5 Off Off On Off Output 3 On when Remote 2 asserted
6 On Off On Off Output 3 On when Remote 3 asserted
7 Off On On Off Flash Output 3 when Remote 1 asserted
8 On On On Off Flash Output 3 when Remote 2 asserted
9 Off Off Off On Flash Output 3 when Remote 3 asserted
10 On Off Off On Output 3 On when Remote 1 or Remote 2
asserted
11 Off On Off On Output 3 On when Remote 1 asserted
and Remote 2 not asserted
12 On On Off On Output 3 On when Remote 1 not
asserted and Remote 2 asserted
13 Off Off On On Output 3 On when Remote 1 asserted
and Remote 2 asserted
14 On Off On On Reserved for future assignment
15 Off On On On Latching Mode selection for Output 3
16 On On On On Momentary Mode selection for Output 3
Fig 15-6: Output 3 Configuration Settings
15.3.5. Flash Rate Preset Potentiometer
This preset potentiometer sets the rate at which the mains output is switched on/off
when one of the Flash Output settings is selected. The range of adjustment is from
0.5 seconds to 2 seconds.