Manual

Table Of Contents
Chapter 15 - RB-LC3 3 Way Light/Power Controller
Redbox User Handbook 15-5
The available settings for output 2, configured using switches Sw5 to Sw8, are
detailed below:
Setting
No
Sw5 Sw6 Sw7 Sw8 Description
1 Off Off Off Off Flash Output 2 when telephone rings
Output 2 On when telephone is off-hook
2 On Off Off Off Output 2 On when telephone is off-hook
3 Off On Off Off Flash Output 2 when telephone rings
4 On On Off Off Output 2 On when Remote 1 asserted
5 Off Off On Off Output 2 On when Remote 2 asserted
6 On Off On Off Output 2 On when Remote 3 asserted
7 Off On On Off Flash Output 2 when Remote 1 asserted
8 On On On Off Flash Output 2 when Remote 2 asserted
9 Off Off Off On Flash Output 2 when Remote 3 asserted
10 On Off Off On Output 2 On when Remote 1 or Remote
2 asserted
11 Off On Off On Output 2 On when Remote 1 asserted
and Remote 2 not asserted
12 On On Off On Output 2 On when Remote 1 not
asserted and Remote 2 asserted
13 Off Off On On Output 2 On when Remote 1 asserted
and Remote 2 asserted
14 On Off On On Reserved for future assignment
15 Off On On On Latching Mode selection for Output 2
16 On On On On Momentary Mode selection for Output 2
Fig 15-5: Output 2 Configuration Settings