Manual

Table Of Contents
62
Redbox User Handbook No 3
GENERAL INTERFACES
GENERAL INTERFACES - R B -LC3
10
Setting
No
Sw9 Sw10 Sw11 Sw12 Description
1 Off Off O Off
Flash Output 3 when telephone rings.
Output 3 On when telephone is
off-hook
2 On Off Off Off
Output 3 On when telephone is
off-hook
3 Off On Off Off Flash Output 3 when telephone rings
4 On On O Off Output 3 On when Remote 1 asserted
5 Off Off On Off Output 3 On when Remote 2 asserted
6 On Off On Off Output 3 On when Remote 3 asserted
7 Off On On Off
Flash Output 3 when Remote 1
asserted
8 On On On Off
Flash Output 3 when Remote 2
asserted
9 Off Off O On
Flash Output 3 when Remote 3
asserted
10 On Off Off On
Output 3 On when Remote 1 or
Remote 2 asserted
11 Off On Off On
Output 3 On when Remote 1 asserted
and Remote 2 not asserted
12 On On Off On
Output 3 On when Remote 1 not
asserted and Remote 2 asserted
13 Off O On On
Output 3 On when Remote 1 asserted
and Remote 2 asserted
14 On Off On On Reserved for future assignment
15 Off On On On Reserved for future assignment
16 On On On On Reserved for future assignment
Fig 10-6: Output 3 Configuration Settings.
Flash Rate Preset Potentiometer
This preset potentiometer sets the rate at which the mains output is switched on/off when
one of the Flash Output settings is selected. The range of adjustment is from 0.5 seconds to
2 seconds.