Handbook

Table Of Contents
Redbox User Handbook No 3
61
GENERAL INTERFACES - RB-LC3
GENERAL INTERFACES
10
13 O O On On
Output 1 On when Remote 1 asserted and Remote
2 asserted
14 On O On On Reserved for future assignment
15 O On On On Latching Mode selection for Output 1
16 On On On On Momentary Mode selection for Output 1
Fig 10-4: Output 1 Conguration Setting.
The available settings for output 2, congured using switches Sw5 to Sw8, are
detailed below:
Setting
No
Sw5 Sw6 Sw7 Sw8 Description
1 O O O O
Flash Output 2 when telephone rings.
Output 2 On when telephone is o-hook
2 On O O O Output 2 On when telephone is o-hook
3 O On O O Flash Output 2 when telephone rings
4 On On O O Output 2 On when Remote 1 asserted
5 O O On O Output 2 On when Remote 2 asserted
6 On O On O Output 2 On when Remote 3 asserted
7 O On On O Flash Output 2 when Remote 1 asserted
8 On On On O Flash Output 2 when Remote 2 asserted
9 O O O On Flash Output 2 when Remote 3 asserted
10 On O O On Output 2 On when Remote 1 or Remote 2 asserted
11 O On O On
Output 2 On when Remote 1 asserted and Remote
2 not asserted
12 On On O On
Output 2 On when Remote 1 not asserted and
Remote 2 asserted
13 O O On On
Output 2 On when Remote 1 asserted and Remote
2 asserted
14 On O On On Reserved for future assignment
15 O On On On Latching Mode selection for Output 2
16 On On On On
Momentary Mode selection for
Output 2
Fig 10-5: Output 2 Conguration Settings.