Command Description Response
SSR:n Set sample rate where ACK: or NAK:
n = 0 (32kHz)
n = 1 (44.1kHz)
n = 2 (48kHz)
n = 3 (64kHz)
n = 4 (88.2kHz)
n = 5 (96kHz)
SST:hhmmss Set system time where ACK: or NAK:
hh = hours (0-23)
mm = minutes (0-59)
ss = seconds (0-59)
SSW:n Set sample width where ACK: or NAK:
n = 0 (16bit)
n = 1 (24bit)
UID: **Unit ID request UID:DS2
UNL: Disable control lock ACK: or NAK:
VER: Version request where VER:Vy.yyy,Vzzzz
y.yyy = rmware version
zzzz = display version
** Supported in Bootstrap mode
Upgrading Firmware
Occasionally, it may be necessary to upgrade the rmware on the delay synchroniser to add
new functionality and x software bugs. New rmware updates will be made available from
time to time on the Sonifex website. Visit www.sonifex.co.uk for details.
The rmware is upgraded using the Serial Control Interface - SCI. This PC software
downloads the new rmware and initiates the upgrade process. To upgrade the rmware,
select the required rmware le in the SCI upgrade rmware section. The delay synchroniser
will automatically reboot and enter the bootstrap mode prior to the transfer of the rmware
le. The SCI software downloads the rmware to internal memory, and then erases the
current rmware before programming the update. When the rmware is complete, the unit
reboots with the new rmware.
Please note: Firmware les can take several minutes to transfer to the delay synchroniser at
lower baud rates. To speed up the process, select a higher baud rate prior to transferring the