Handbook
34
Redbox User Handbook No 1
DIGITAL AUDIO CONVERTERS - RB-SC2
DIGITAL AUDIO CONVERTERS
4
Error messages
The following error messages can be returned for illegal commands
Err:01 - return if Command Not Found
Err:02 - return if Missing Parameter
Err:04 - return if Parameter out of range
Upgrading Firmware
Occasionally, it may be necessary to upgrade the rmware on the RB-SC2 to add new
functionality and x software bugs. New rmware updates will be made available from time
to time on the Sonifex website. Visit www.sonifex.co.uk for details.
The rmware is upgraded using the Serial Control Interface - SCI. This PC software
downloads the new rmware and initiates the upgrade process. To upgrade the rmware,
select the required rmware le in the SCI upgrade rmware section. The RB-SC2 will
automatically reboot and enter the bootstrap mode prior to the transfer of the rmware le.
The SCI software downloads the rmware to internal memory, and then erases the current
rmware before programming the update. When the rmware is complete, the unit reboots
with the new rmware.
Please note: Firmware les can take several minutes to transfer to the RB-SC2 at lower
baud rates. To speed up the process, select a higher baud rate prior to transferring the new
rmware.
Technical Specication RB-SC2
Connections
Digital Inputs: 2 x AES/EBU XLR 3 pin female
2 x S/PDIF RCA phono
2 x TOSLink optical input
Digital Outputs: 2 x AES/EBU XLR 3 pin plug
2 x S/PDIF RCA phono socket
2 x TOSLink optical output
Sync Inputs: 1 x AES/EBU XLR 3 pin female
1 x Word Clock BNC
1 x Video Input (optional)
Video Sync Specs: The RB-SYD Digital video sync board will accept 270Mbps
SD-SDI and HD-SDI signals covered by SMPTE-259-M-C (SD)
and SMPTE-292M (HD).
The RB-SYA Analogue video sync board will accept a
composite signal of NTSC (525), PAL (625) & SECAM (625)
signals covered by SMPTE-170-M (NTSC) and ITU-R BT.470-6
(PAL & SECAM).