Command Description Response
SRQ: Status Request where -SRQ:aa_bb_cc_dd_ee_fg_hhhh_ii
aa = Input1 lock status
bb = Input2 lock status
where 00 = unlocked and 01 = locked
cc = Restore ash
dd = Sync ash
where 00 = Not ashing and 01 = ashing
ee = Output switched
where 00 = Switched and 01 = Not switched
fg:
f = alarm status and g = program level status
where f and g are hex values built from the sum of:
1 = Input 1 L
2 = Input 1 R
4 = Input 2 L
8 = Input 2 R
For example if input 1 was in a good state but input 2 was alarmed the value would be C3
Alarm status = Input 2L + Input 2R = 4+8 = C
Program level status = Input 1L + Input 1R = 1+2=3
hhhh: Remote port status
where hhhh represents hex values built from the sum of:
01: Main alarm
02: Aux alarm\remote stop indicator
04: Auto indicator
08: Remote start indicator
10: Source indicator
Follow above example for further clarication
ii: Current special mode
where ii is a hex value based on which mode is selected:
00: No special mode
01: Signal detection mode
02: Force main mode
04: Emergency overide mode
08: Detection enabled/disabled mode