Handbook

116
Redbox User Handbook No 1
Operation On Loss Of One Channel
DIPSwitch 7 denes how the unit reacts to the loss of one channel.
DIPSwitch 7 Description
On When on, the unit will output the remaining channel to the lost
channel to create a dual mono output.
O When o, the unit will simply mute the lost channel and continue.
Operation On Loss Of Lock
DIPSwitch 8 denes whether the unit treats a loss of lock as a severe event or as a simple
loss of level.
DIPSwitch 8 Description
On When on, the unit will treat the loss of lock condition as severe and
the unit will switch to the Aux input after 2 seconds.
O When o, the unit will treat the loss of lock no dierently to a loss of
level.
Remote Stop Operation
DIPSwitch 9 denes whether the remote stop is operational. Used for stopping external
equipment when the unit recovers from a switched state.
DIPSwitch 9 Description
On When on and Remote Start is set to momentary, pin 4 will close to pin
11 on the remote connector for half a second. Remote start operation
is also aected. If no level is detected on the channel which has been
switched to, the remote start pulse will repeat every ten seconds.
Please note that the aux alarm will not work in this mode.
O When o, the aux alarm operates normally.
Switching Operation
DIPSwitch 10 denes whether the unit switches when it loses lock or the level drops, i.e. any
failure condition. This is so that the unit can signal a failure without actually switching.
DIPSwitch 10 Description
On When on, the unit will not switch on any fail condition.
O When o, the unit will switch on any fail condition.
Firmware Mode
DIPSwitch 12 denes the boot up mode.
DIPSwitch 12 Description
On When on, the unit boots in bootstrap mode.
O When o, the unit boots in ‘normal’ conguration.
10
SYNCHRONISERS, DELAYS &
SILENCE DETECTORS
SYNCHRONISERS, DELAYS & SILENCE DETECTORS - RB-DSD1