Handbook

96
Redbox RB-PD2 User Handbook
8
SYNCHRONISERS, DELAYS &
SILENCE DETECTORS
SYNCHRONISERS, DELAYS & SILENCE DETECTORS - RB-PD2
Command Description Response
VRS: Request remote VRS:m_n_o_p_q_r_s_t_u_v
settings where: _w_x_y_z
m = remote input 1 setting
n = remote input 2 setting
o = remote input 3 setting
p = remote input 4 setting
q = remote input 5 setting
r = remote input 6 setting
s = remote input 7 setting
t = remote input 8 setting
u = remote output 1 setting
v = remote output 2 setting
w = remote output 3 setting
x = remote output 4 setting
y = remote output 5 setting
z = remote output 6 setting
** Supported in Bootstrap mode
Upgrading Firmware
Occasionally, it may be necessary to upgrade the rmware on the RB-PD2 to add new
functionality and x software bugs. New rmware updates will be made available from
time to time on the Sonifex website. Visit www.sonifex.co.uk for details.
The rmware is upgraded using the Serial Control Interface - SCI. This PC software
downloads the new rmware and initiates the upgrade process. To upgrade the rmware,
select the required rmware le in the SCI upgrade rmware section. The RB-PD2 will
automatically reboot and enter the bootstrap mode prior to the transfer of the rmware le.
The SCI software downloads the rmware to internal memory, and then erases the current
rmware before programming the update. When the rmware is complete, the unit reboots
with the new rmware.
Please note: Firmware les can take several minutes to transfer to the RB-PD2 at lower baud
rates. To speed up the process, select a higher baud rate prior to transferring
the new rmware.