Handbook
Redbox RB-PD2 User Handbook
95
8
SYNCHRONISERS, DELAYS & SILENCE DETECTORS - RB-PD2
SYNCHRONISERS, DELAYS &
SILENCE DETECTORS
Command Description Response
q = record source setting
r = record sample rate setting
s = record sample width setting
t = input peak digits setting
u = output gain setting
v = analogue mute status
w = digital mute status
x = bypass status
y = control lock status
z = delay build/exit speed setting
SSC:n Set source where: ACK: or NAK:
n = 0 (analogue)
n = 1 (analogue sync)
n = 2 (digital)
SSF:c Set delay start play le where: ACK: or NAK:z
c = “\path\lename”
(c=“\lename” for les in root directory)
z = error message
SSP:n Set safe period length where: ACK: or NAK:
n = dump length in
milliseconds (100ms resolution)
SSR:n Set sample rate where: ACK: or NAK:
n = 0 (32 kHz)
n = 1 (44.1 kHz)
n = 2 (48 kHz)
SSW:n Set sample width where: ACK: or NAK:
n = 0 (16bit)
n = 1 (24bit)
UID: **Unit ID request UID:PD2
UNL: Disable control lock ACK: or NAK:
VER: Version request where VER:Vy.yyy,Vzzzz
y.yyy = rmware version
zzzz = display version