Handbook

SignalLED User Handbook
SIGNALLED STUDIO ILLUMINATED SIGNS
SIGNALLED STUDIO ILLUMINATED SIGNS
SignalLED User Handbook
SIGNALLED STUDIO ILLUMINATED SIGNS
SIGNALLED STUDIO ILLUMINATED SIGNS
58
To get access to the cable connection block and the mode switches, which are on the PCB
inside the sign, the door on the underside of the end plastic moulding must be opened.
To open the door push the clip towards the sign and
pull down on the small lip. See Fig 5. Do not attempt
to remove the door from the end moulding. Access
to the connection block and the mode switches is
possible with the door fully open.
Fig 5: Opening The Access Door
The sign can be connected and powered either
with the supplied DC power supply, or with a
regulated DC supply rated 5V to 7V DC, 0.5mA
minimum. On the supplied DC power supply,
the +6V is indicated with a dashed white line on
one of the cables. Before tting the international
wall adapters to the power supply the tted
connector cover must be removed.
Fig 6: Mode Settings & Connection Block
Mounting The Sign To The Wall Plate
The sign is tted by locating the four internal hanger plate hooks into the four slots in the
wall mount plate.
Once located, hold the sign around the end moulding of the SignalLED assembly (where
the door is tted) and press down into its nal position. The sign retaining pins will clip into
the indentations on the side of the wall mount plate and this should result in a click as the
plastic pins move into their nal position. See Figs. 7 & 8.
Fig 7: Align The Sign to The Wall Plate Fig 8: Fitting The Sign to The Wall Plate
Fig 12: Removing the Right Hand Flush Wall Moulding Fig 13: Right Hand Conversion Re-assembly
Left Hand Side Fitting of the Conversion Kit
Note: With this conversion you will be removing the PCB from the sign so full anti-static
precautions must be taken to protect the PCB from damage. Failure to do so may result in
the sign not working and invalidating the warranty.
1) Open the end cover on the right hand ush mount assembly by removing the self-
tapping screw with a No.1 pozi-drive screwdriver.
2) Remove the 2 small screws that hold the PCB into the right hand ush mount
assembly and withdraw the PCB. Place the PCB on an antistatic surface.
3) Remove the right hand ush mount assembly by unscrewing the 4 screws that x the
end moulding to the aluminium tube. These are located inside at the bottom of the
end moulding.
4) Align the 4 pins of the extrusion end cover with the screw holes in the exposed end
of the aluminium tube. Note the orientation of the cut-out with the clear sign board
and press t the end cover fully onto the aluminium tube.
5) Open the end cover on the left hand ush mount assembly by removing the self-
tapping screw with a No.1 pozi-drive screwdriver.
6) Remove the ush wall mount moulding from the end moulding by unscrewing the 4
screws visible under the cover.
7) Replace the PCB into the left hand end moulding aligning the PCB edge with the
guide tracks in the aluminium extrusion. Ret the 2 small screws that hold the PCB,
taking care not to over tighten and strip the plastic.
8) Fit the internal hanger plate into the end wall mount moulding. Align the semi-
circular cut-out in the hanger plate with the raised section above the serial number
label, which indicates the bottom of the assembly. Also make sure that the hanger
plate ts into the slots in the wall mount moulding.