SignalLED User Handbook
2
INSTALLATION
INSTALLATION
Installation
Mounting The Sign
Route the signal and power supply cables before nalising the mounting of the sign. These
cables can be routed either through the aperture, or through the cable cut-outs in the back
of the wall mount moulding.
The LED sign should be mounted on a rm solid surface. The sign is supplied with a
NPVOUJOHLJUDPNQSJTJOHYXBMMQMVHTBOEYMBSHFøBOHFTDSFXT
Note: You’ll need the following tools to mount the sign: an electric drill tted with a 6mm
diameter masonry drill bit, a No.1 Pozi-drive screwdriver and a spirit level.
- Drill 2 holes, approximately 34mm deep, using a 6mm diameter masonry drill at the
pitch shown on the drawings.
*OTFSUUIFXBMMQMVHTøVTIXJUIUIFTVSGBDF
- Use a spirit level on the aluminium tube section to set the sign level before fully
tightening.
The screws can also be used for xing into wood. For correct tting drill a small pilot hole
into the wood before tting the screw.
Opening The End Covers
To get access to the sign mounting points, the side covers need to be opened. Use a
No.1 Pozi-drive screwdriver to unscrew the side cover and gently slide the cover forward
approximately 8mm until it reaches the stops. Pivot open the cover. Please note: do not to
use excessive force when opening the cover.
LD-20F1 & LD-40F1 Flush Sign Mounting Requirements
5IJTTJHOJTUPCFNPVOUFEøVTIUPBXBMM.JOJNVNDMFBSBODFTGSPNUIFTJHOUPBOBEKBDFOU
wall or ceiling are shown below.
Fig 2-1: LD-20F1 & LD-40F1 Flush Sign Mounting Requirements
An absolute minimum of 60mm is required for the opened end cap, a right angled
screwdriver would be needed to screw (unscrew) the end cap retaining screw.
30mm minimum clearance between
ceiling and mounting hole
Minimum clearance
to an adjacent
wall using 2 small
No. 1 Pozi-drive
screwdriver.
Wall Ceiling
30mm
200mm
LD-40F1 520 mm
LD-20F1 316 mm
= Mounting hole