PROGRAMMING
3
PROGRAMMING
Programming Colour & Illumination Modes
SignalLED signs bought after 1st December 2010 are
programmed using a separate handheld remote control,
instead of being programmed using DIPSwitches on the sign.
Please note that the remote control must be ordered
separately, LD-RPC. Please contact your Sonifex distributor
for ordering information.
Although the SignalLED is delivered as standard to indicate a certain colour when a pull-low
(to 0V) input signal is applied, the sign is programmable to allow a number of dierent
display modes and uses. For example, the sign can be made to switch between 4 colours,
one for each of the input conditions below. The sign can also illuminate a certain colour
when no input signal is connected, i.e. it can be permanently illuminating, or it can be made
to switch from one colour to another on application of an input signal.
Setting The Colour & Display Mode(s) of The Sign
The sign can be set to illuminate in 4 dierent states according to the combination of
the 2 x pull-low signalling inputs present at the input connector block:
t $POOFDUQJOUP7UPTFMFDUJOQVU
t $POOFDUQJOUP7UPTFMFDUJOQVU
For each of the 4 states, the following features can be adjusted and set:
t %JWJEF1PJOUo5IJTBMMPXTZPVEJWJEFUIFTJHOJOUPUXPTFQBSBUFTFDUJPOTUPTFUUIF
size of each section and to set the size of a ‘dead area’ in between the two sections, if
required.
t $PMPVSPGFBDITFDUJPO
t #SJHIUOFTTPGPWFSBMMTJHOJMMVNJOBUJPO
t .PEFPGTJHOPQFSBUJPOTFMFDUBCMFGSPNPOPòøBTIQVMTFBOEGBEF
Enter Programming Mode
To enter programming mode, open the Access Door (See Fig 2-5) which exposes the
infra-red receiver. Then point the remote control unit at the opening and press & hold the
PROGRAM (7) button for 3 seconds until the LEDs in the main sign quickly cascade away & to
the opening. This indicates that the unit is in the Programming Mode.
To exit the Programming Mode, press & hold the PROGRAM (7) button until the LEDs
cascade away & to the receiver again.