Appendix F - Securing the SonicWALL
Mounting the SonicWALL PRO 200 and SonicWALL PRO 300
The SonicWALL PRO 200 and SonicWALL PRO 300 are designed to be mounted in a
standard 19-inch rack mount cabinet. The following conditions are required for proper
installation:
Use the mounting hardware recommended by the rack manufacturer and ensure
that the rack is adequate for the application.
Four mounting screws, compatible with the rack design, must be used and hand
tightened to ensure secure installation. Choose a mounting location where all four
mounting holes line up with those of the mounting bars of the 19-inch rack mount
cabinet.
Mount in a location away from direct sunlight and sources of heat. A maximum am-
bient temperature of 104º F (40º C) is recommended.
Route cables away from power lines, fluorescent lighting fixtures, and sources of
noise such as radios, transmitters, and broadband amplifiers
Ensure that no water or excessive moisture can enter the unit.
Allow unrestricted airflow around the unit and through the vents on the side of the
unit. A minimum of 1 inch (25.44mm) clearance is recommended.