Weld Starts
Ready
CONFIDENCE, AND SHALL NOT BE DISCLOSED, USED OR DUPLICATED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE PRIOR WRITTEN PERMISSION OF SONICS & MATERIALS INC.,
NEWTOWN, CT. THIS LEGEND SHALL BE MARKED ON ANY REPRODUCTIONS HEREOF IN WHOLE OR
CONFIDENTIAL INFORMATION
Job address lines must be stable 50 ms
before the impulse start contact closes.
They must remain stable until Ready
indicates that the cycle has started.
THE INFORMATION AND DATA CONTAI NED HEREIN IS PROPRIETARY AND IS SUBMITTED IN
IN PA R T. RECEIPT OF THIS DOCUMENT SHALL BE DEEMED TO BE AN ACCEPTA NCE OF THE
Timing Diagram - Automation Controls
End of Weld
Good Part / Bad Part Signals (2)
Job Address Lines (4)
Impulse Start Command
Good/Bad Part signals are both cleared when the cycle begins.
The Good Part or Bad Part signal is set 30 ms before Ready returns
True at the end of the weld cycle. If there are any limit violations, the
Bad Part signal will be True. Otherwise, the Good Part signal will be True.
When the impulse contact is recongnized, the weld cycle will begin (maximum of 50 ms
after the contact closure. The Ready signal will indicate NOT Ready until the cycle is complete.
Weld cycle time
Impulse contact must be closed a minimum of 50 ms to start an automatic cycle.
The contact must be released prior to the end of the cycle.
1. The job address lines are active only when the keypad is "locked".
Jobs will be recalled from the job storage area to the active weld
definition within 30 ms of setting the job code address lines. Job
code 0 is reserved and will not change the active job values.
E-3182