Manual

I N S T R U C T I O N M A N U A L M O D E L G X L P O W E R S U P P LY
29
P R I N T L I N E O U T P U T
At the end of every weld cycle, the power supply sends an ASCII print line
which includes the data for weld time, distance, energy, maximum power
and alarm status. This line can be directed to a printer, a PLC ASCII card or
a computer running any terminal program that will present the information.
(The hyperterminal program is included with any PC under the
Accessories/Communications directory. Note that the communication
channel is not bi-directional at this time; it is an output print line only.)
The transmission settings are fixed at: 19200 bits per second, 8 data bits,
parity = None, 1 stop bit and flow control = None. The cabling and connector
arrangement is set to use a standard 9-pin Null Modem cable, the same
RS232 cable that would be used to connect two PC computers together.
The order of the data is the same for each line and the length of the line does
not change with the values of the data. Line length could be important if a
receiving device is attempting to parse the data for other uses. It means that
the data items are always in the same place and therefore much easier to
remove from the print line.
The end of each print line contains two non-printable characters, a carriage
return followed by a line feed character. These characters are standard
RS232 control characters to position the cursor location to the beginning of
the next line on the screen or print page.
Sample Print line:
123 4 5 6 78
005647 00.48 sec 0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----
005648 00.47 sec 0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----
005649 00.45 sec 0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----
005650 00.48 sec 0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----
005651 00.47 sec 0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----
005652 00.45 sec 0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----
005653 00.48 sec 0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----
005654 00.47 sec 0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----
005655 00.45 sec 0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----
005656 00.49 sec 0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----
005657 00.46 sec 0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----
005658 00.46 sec 0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----
005659 00.47 sec 0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----
NOTE: Use of a
printer causes the
cycle to be extended
by approximately 100
ms.
NOTE: The Print Line
option default is
“OFF.” Switch 5
determines OFF/ON
(see page 52).
Go To Top Of Document