Clock Radio User Manual
Table Of Contents
- CP-UM-5093E-04.pdf
- SAFETY PRECAUTIONS
- Contents
- Chapter 1. GENERAL
- Chapter 2. NAMES & FUNCTIONS OF PARTS
- Chapter 3. MOUNTING
- Chapter 4. WIRING
- 4-1 Wiring Precautions
- 4-2 Compensating Lead
- 4-3 Terminal Connections
- 4-4 Layout of Terminals and Recommended Lead Draw-out Direction
- 4-5 Connecting the Ground and Power Supply
- 4-6 Wiring of Standard and Add-on Terminal Base
- 4-7 Connecting Inputs (analog inputs)
- 4-8 Connecting control outputs (outputs 1, 2)
- 4-9 Connecting auxiliary outputs (outputs 2, 3)
- 4-10 Connecting Event Output (relay output)
- 4-11 Connecting Time Event Output (open-collector)
- 4-12 Connecting External Switch (RSW) Input
- 4-13 Connecting for Communications
- 4-14 Isolating Inputs and Outputs
- Chapter 5. FUNCTIONS
- Chapter 6. OPERATION
- Chapter 7. PARAMETER SETUP
- Chapter 8. PROGRAM SETUP
- Chapter 9. TROUBLESHOOTING
- Chapter 10. SPECIFICATIONS
- Chapter 11. CALIBRATION
- Index

Chapter 7. PARAMETER SETUP
7-29
No. Item Code Item Factory User Setting
Setting Setting
31 C 3 1 –
32 C 3 2 –
33 C 3 3 –
34 C 3 4 –
35 C 3 5 –
36 C 3 6 –
37 C 3 7 –
38 C 3 8 –
39 C 3 Q –
40 C 4 0 –
41 C 4 1 –
42 C 4 2 –
43 C 4 3 –
44 C 4 4 –
45 C 4 5 0
46 C 4 6 0
47 C 4 7 0
48 C 4 8 1000
49 C 4 q 0
[Note]
“– – – –” is displayed and setting is not possible.
0: 3-position control disabled
1: 3-position control enabled
[Note]
On models not supporting 3D output, “– – – –” is
displayed and setting is not possible.
0: PV1
1: SP1
2: Deviation1
3: MV1
4 to 7: NOP
8: MFB
9 to 11: NOP
[Note]
On models not supporting auxiliary output 1, “– – – –”
is displayed and setting is not possible.
When set to NOP (or to MFB on models other than 2G
output models), output is fixed to 4mA.
When set to SP or deviation, output in the READY
mode is fixed to 4mA.
-1999 to 9999U
-199.9 to 999.9%
[Note]
When the auxiliary output type is MV or MFB, the unit is
%. Otherwise, the unit is U.
0: PV1
1: SP1
2: Deviation1
3: MV1
4 to 7: NOP
8: MFB
9 to 11: NOP
[Note]
When auxiliary output 2 is not supported, “– – – –” is
displayed and setting is not possible.
When set to NOP (or to MFB on models other than 2G
output models), output is fixed to 4mA.
When set to SP or deviation, output in the READY
mode is fixed to 4mA.
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Unused
3-position control
Auxiliary output 1
type
Auxiliary output 1
lower limit (4mA)
Auxiliary output 1
upper limit (20mA)
Auxiliary output 2
type