User Manual

SPECIFICATIONS
Electrical:
- Power: Nominal 12V (11-16V )
- Current draw: 45mA average, 80mA peak
- Reverse voltage protection
- Immune to ESD and transients per SAE standard J1113
- EMC compatible per SAE standard J1113
Mechanical:
- Dimensions: 5.7"L x 2.6"W x 1.14"H
- Weight: 4.24 Oz (0.265Lb)
Environmental:
- Operating temperature range: -10 to +70°C
- Storage temperature: -25 to + 85°C
- Meets SAE standards J1455
- Chemical resistance, corrosion and humidity per MIL-STD-810
RF:
- Range: 300' open field, 90' minimum when installed on a fire or emergency truck
- Secured digitally encoded interference free communications
- Any combination of base stations or headsets for a total of 40 headsets working
together in close proximity.
FCC Compliance:
Pending FCC approval, this device complies with FCC Rules Part 15. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference that may be received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by Firecom can void
the user’s authority to operate the equipment.
If a problem persists in the device, contact Firecom for a Return Merchandise
Authorization (RMA) number. Return the device for replacement or repair.
CONTACT: Firecom 1-800-527-0555
7340 SW Durham Road
Portland, OR 97224
USA
8