Safety data sheet

Page 3/7
Safety data sheet
according to 1907/2006/EC, Article 31
Printing date 11.09.2015 Revision: 23.10.2014Version: 3
Trade name: SONAX Glass Cleaning Star
(Contd. of page 2)
41.0
SECTION 8: Exposure controls/personal protection
8.1 Control parameters
Ingredients with limit values that require monitoring at the workplace:
107-98-2 1-Methoxy-2-propanol
WEL (Great Britain) Short-term value: 560 mg/m³, 150 ppm
Long-term value: 375 mg/m³, 100 ppm
Sk
IOELV (EU) Short-term value: 568 mg/m³, 150 ppm
Long-term value: 375 mg/m³, 100 ppm
Skin
64-17-5 ethanol
WEL (Great Britain) Long-term value: 1920 mg/m³, 1000 ppm
DNELs
107-98-2 1-Methoxy-2-propanol
Oral DNEL 3.3 mg/kg (consumer) (long-term / systemic effects)
Dermal DNEL 18.1 mg/kg (consumer) (long-term / systemic effects)
50.6 mg/kg (worker) (long-term / systemic effects)
Inhalative DNEL 43.9 mg/m³ (consumer) (long-term / systemic effects)
553.5 mg/m³ (worker) (short-term / local effects)
369 mg/m³ (worker) (long-term / systemic effects)
64-17-5 ethanol
Oral DNEL 87 mg/kg (consumer) (long-term exposure - systemic effects)
Dermal DNEL 206 mg/kg bw/day (consumer) (long-term exposure - systemic effects)
343 mg/kg bw/day (worker) (lon-term exposure - systemic effects)
Inhalative DNEL 950 mg/m³ (consumer) (acute short-tem exposure - local effects)
114 mg/m³ (consumer) (long-term exposure - systemic effects)
1900 mg/m³ (worker) (acute short-tem exposure - local effects)
950 mg/m³ (worker) (long-term exposure - systemic effects)
PNECs
107-98-2 1-Methoxy-2-propanol
PNEC 100 mg/l (STP)
2.47 mg/kg (gro)
41.6 mg/kg (sediment (fresh water))
4.17 mg/kg (sediment (sea water))
100 mg/l (water (intermittent release))
10 mg/l (water (fresh water))
1 mg/l (water (sea water))
64-17-5 ethanol
PNEC 3.6 mg/kg (sediment (fresh water))
2.9 mg/kg (sediment (sea water))
0.63 mg/kg (soil)
0.96 mg/l (water (fresh water))
0.79 mg/l (water (sea water))
Additional information:
The lists valid during the making were used as basis.
8.2 Exposure controls
Suitable technical control devices
Ensure good ventilation. This can be achieved by localised extraction or general ventilation.If this is not
sufficient to keep the concentration below the occupational exposure limit, suitable breathing protection is to be
worn.
(Contd. on page 4)
GB