Safety data sheet
Page 3/8
Safety data sheet
according to 1907/2006/EC, Article 31
Printing date 12.09.2015 Revision: 27.01.2015Version: 4
Trade name: SONAX Xtreme Wheel Cleaner plus
(Contd. of page 2)
41.0
SECTION 5: Firefighting measures
5.1 Extinguishing media
Suitable extinguishing agents:
Use fire extinguishing methods suitable to surrounding conditions.
5.2 Special hazards arising from the substance or mixture
No further relevant information available.
5.3 Advice for firefighters
Protective equipment:
The normal measures for firefighting are to be taken.
Additional information
Cool endangered receptacles with water spray.
Collect contaminated fire fighting water separately. It must not enter the sewage system.
SECTION 6: Accidental release measures
6.1 Personal precautions, protective equipment and emergency procedures
Ensure adequate ventilation
Wear protective equipment. Keep unprotected persons away.
6.2 Environmental precautions:
Do not allow to penetrate the ground/soil.
Do not allow to enter sewers/ surface or ground water.
6.3 Methods and material for containment and cleaning up:
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
Dispose contaminated material as waste according to item 13.
6.4 Reference to other sections
See Section 7 for information on safe handling.
See Section 8 for information on personal protection equipment.
See Section 13 for disposal information.
SECTION 7: Handling and storage
7.1 Precautions for safe handling
Ensure good ventilation/exhaustion at the workplace.
Information about fire - and explosion protection:
Pressurized container: protect from sunlight and do not expose to temperatures exceeding 50 °C. Do not pierce
or burn, even after use.
7.2 Conditions for safe storage, including any incompatibilities
Storage:
Requirements to be met by storerooms and receptacles:
Prevent any seepage into the ground.
Observe official regulations on storing packagings with pressurised containers.
Information about storage in one common storage facility:
Store away from oxidising agents.
Do not store together with alkalis (caustic solutions).
Do not store together with acids.
Store away from foodstuffs.
Further information about storage conditions:
Store receptacle in a well ventilated area.
Store in a cool place. Heat will increase pressure and may lead to the receptacle bursting.
Protect from heat and direct sunlight.
Protect from frost.
Recommended storage temperature: 20 °C.
7.3 Specific end use(s)
No further relevant information available.
GB