Safety data sheet

Page 3/6
Safety data sheet
according to 1907/2006/EC, Article 31
Printing date 12.09.2015 Revision: 24.02.2015Version: 3
Trade name: SONAX Xtreme Brillinat Wax 1 "Hybrid NPT"
(Contd. of page 2)
41.0
8.2 Exposure controls
Suitable technical control devices
Ensure good ventilation. This can be achieved by localised extraction or general ventilation.If this is not
sufficient to keep the concentration below the occupational exposure limit, suitable breathing protection is to be
worn.
Personal protective equipment:
General protective and hygienic measures:
The usual precautionary measures are to be adhered to when handling chemicals.
Wash hands before breaks and at the end of work.
Keep away from foodstuffs, beverages and feed.
Respiratory protection:
Not required in normal cases
Ensure good ventilation/exhaustion at the workplace.
Protection of hands:
Not required in normal cases
Eye protection:
Not required in normal cases
SECTION 9: Physical and chemical properties
9.1 Information on basic physical and chemical properties
General Information
Appearance:
Form:
Fluid
Colour:
Light blue
Odour:
Characteristic
Odour threshold:
Not determined.
pH-value:
7.0 - 8.0
Change in condition
Melting point/Melting range:
Undetermined.
Boiling point/Boiling range:
100 - 220 °C
Flash point:
Not applicable.
Flammability (solid, gaseous):
Not applicable.
Ignition temperature:
Decomposition temperature:
Not determined.
Self-igniting:
Product is not selfigniting.
Danger of explosion:
Product does not present an explosion hazard.
Explosion limits:
Lower:
Explosion limits components:
Hydrocarbons, C11-C12, isoalkanes, < 2% aromatics:
0,6Vol%
Upper:
Explosion limits components:
Hydrocarbons, C11-C12, isoalkanes, < 2% aromatics:
7,0Vol%
Not determined.
Vapour pressure:
Not determined.
Density at 20 °C:
0.92 - 0.93 g/cm³
Relative density
Not determined.
Vapour density
Not determined.
Evaporation rate
Not determined.
Solubility in / Miscibility with
water:
Partly miscible.
Partition coefficient (n-octanol/water):
Not determined.
Viscosity:
Flow time at 20 °C
>60 s (DIN EN ISO 2431/6mm)
(Contd. on page 4)
GB