Operation Manual

Maintenance and care
23
Regular checks
Check safety devices regularly, every year at the very least, to ensure they function correctly. Refer to EN 12453:2000.
Safety devices that are sensitive to pressure (e.g. safety switch unit) should be checked every four weeks to ensure they function correctly,
see EN 60335-2-95:11-2005.
In particular, check whether the drive reverses correctly when it encounters a 50 mm high obstacle lying on the ground. Correctly adjust if necessary
and recheck; an incorrect setting presents a hazard.
Check Behaviour yes/no Possible cause Remedial action
Force cut-off
Use 50 mm object to stop
door wing from closing.
Drive reverses when contact
with object is made
yes Automatic cut-off of
supply is working as
it should
Leave all settings as they are.
no Door incorrectly adjusted Have door correctly adjusted by a person
qualied to do so!
Emergency release
Adopt procedure described in
chapter “Operation/handling
– emergency release”.
Emergency release can be
activated easily (pull 1x,
operator is unlocked)
yes Everything in order!
no Drive stops door.
Door and drive
components are strained.
Emergency release is
defective. Door jam
Adjust door CLOSED end switch or activate
backjump (DIP switch 6 ON).
Repair emergency release
Check door. Refer to maintenance
instructions for the door.
Safety switch unit,
if provided
Open/close door whilst,
at same time, operating
safety switch unit
Door behaves in accordance
with setting of DIP switch
1,2 or 3.
yes Everything in order!
no Broken cable,
loose terminal
DIP switch maladjusted
Switch unit defective
Check wiring, tighten terminal connection.
Correctly adjust DIP switch
Take door drive mechanism out of operation
and ensure it cannot restart by accident.
Contact after-sales service!
Light barrier, if provided
Open/close door whilst,
at same time, interrupting
the light barrier.
Door behaves in accordance
with setting of DIP switch
1,2 or 3.
yes Everything in order!
no Broken cable,
loose terminal
DIP switch maladjusted
Light barrier soiled
Light barrier maladjusted
(bent bracket)
Light barrier defective
Check wiring, tighten terminal connection.
Correctly adjust DIP switch
Clean light barrier
Correctly adjust light barrier
Take door drive mechanism out of operation
and ensure it cannot restart by accident.
Contact after-sales service!