Operation Manual
Maintenance and care
23
Regular checks
Check safety devices regularly, every year at the very least, to ensure they function correctly. Refer to EN 12453:2000.
Safety devices that are sensitive to pressure (e.g. safety switch unit) should be checked every four weeks to ensure they function correctly,
see EN 60335-2-95:11-2005.
In particular, check whether the drive reverses correctly when it encounters a 50 mm high obstacle lying on the ground. Correctly adjust if necessary
and recheck; an incorrect setting presents a hazard.
Check Behaviour yes/no Possible cause Remedial action
Force cut-off
Use 50 mm object to stop
door wing from closing.
Drive reverses when contact
with object is made
yes • Automatic cut-off of
supply is working as
it should
• Leave all settings as they are.
no • Door incorrectly adjusted • Have door correctly adjusted by a person
qualied to do so!
Emergency release
Adopt procedure described in
chapter “Operation/handling
– emergency release”.
Emergency release can be
activated easily (pull 1x,
operator is unlocked)
yes • Everything in order!
no • Drive stops door.
• Door and drive
components are strained.
• Emergency release is
defective. Door jam
• Adjust door CLOSED end switch or activate
backjump (DIP switch 6 ON).
• Repair emergency release
• Check door. Refer to maintenance
instructions for the door.
Safety switch unit,
if provided
Open/close door whilst,
at same time, operating
safety switch unit
Door behaves in accordance
with setting of DIP switch
1,2 or 3.
yes • Everything in order!
no • Broken cable,
loose terminal
• DIP switch maladjusted
• Switch unit defective
• Check wiring, tighten terminal connection.
• Correctly adjust DIP switch
• Take door drive mechanism out of operation
and ensure it cannot restart by accident.
Contact after-sales service!
Light barrier, if provided
Open/close door whilst,
at same time, interrupting
the light barrier.
Door behaves in accordance
with setting of DIP switch
1,2 or 3.
yes • Everything in order!
no • Broken cable,
loose terminal
• DIP switch maladjusted
• Light barrier soiled
• Light barrier maladjusted
(bent bracket)
• Light barrier defective
• Check wiring, tighten terminal connection.
• Correctly adjust DIP switch
• Clean light barrier
• Correctly adjust light barrier
• Take door drive mechanism out of operation
and ensure it cannot restart by accident.
Contact after-sales service!