Operation Manual
Functions and connections
20
Direct socket unit (push-button 1)
NOTE!
Swap connections (terminal 3 + 4) around if drive
is to be used with a side hinged door.
¾ Permissible cable cross-section: max. 1.5 mm².
2
3
4 5
6
1
Terminal 1 + 2 Transformer
Terminal 3 C-rail
Terminal 4 Chain
Terminal 5 + 6 Push-button contact (push-button 1)
CAUTION!
Use the contact (terminal 5 + 6) only for potential-free
normally closed contacts. External voltage may damage
or even destroy the control unit.
Early warning time (DIP 5)
The warning lamp starts to ash after push-button is pressed or the hand-
held transmitter is operated, before the drive starts. If the push-button is
pressed again or the hand-held transmitter operated during the 3 seconds,
the early warning period is ended prematurely.
The early warning time functions in conjunction with both internal lighting
and with a connected warning lamp.
DIP switch 5
OFF deactivated
ON activated, internal lighting and warning lamp with ash
for 3 seconds
Backjump (DIP 6)
NOTE!
With sectional doors, or doors with ceiling guides, you have
the option of enabling the backjump with DIP switch 6
in order to ofoad the operator and door mechanisms.
Easier operation of the emergency release.
This feature serves the purpose of supporting door and drive mechanism.
The drive mechanism moves briey back in a door OPEN direction once
it has reached the door CLOSED end position.
DIP switch 6
OFF deactivated
ON activated
Dened opening and closing
(DIP 7)
NOTE!
With this function, push-button 1/radio channel 1only opens
the door and push-button 2/radio channel 2 closes the door.
1
2
Push-button 1/radio channel 1 open and push-button 2/radio channel 2
close the door. This function can also be used with just 2 push-buttons
or with just a hand-held transmitter.
Requirement:
• DIP switch 8 OFF
• 2 push-buttons connected (DIP switch 2 ON) or 2 hand-held transmitter
buttons programmed.
2
1
ON
3
4
5
6
87
6
DIP switch 7
OFF deactivated
ON activated