Operation Manual
Installation
12
1
HM
3
2
5
4
B
600
0
1
17 18
CAUTION!
Always mount the drive in parallel to the runner rails
of the door.
HM
Lift up drive.
Align ceiling bracket (1). It should be located within a range
of B = 0 ... 600 mm.
Align drive mechanism horizontally to rear centre of door (HM).
Mark position of holes. Drill two holes (Ø 10 x 65 mm deep).
NOTE!
Wear safety goggles when drilling! Check the thickness of the
ceiling, especially in the case of prefabricated garages!
Insert plug (1). Fit two screws (2) with plain washers (3).
Tighten screws (2). Align C-rail (4) at the correct height (use a spirit
level if necessary). If necessary, move screws (5). Tighten screws (5).
19
2
3
5
4
3
N
1
2
4
8
7
3
6
5
1
20
N
FRONT
VORNE
NOTE!
Use screws that are appropriate to the door material.
Wear safety goggles when drilling!
Mount connecting arm (1):
Insert the long bolt (2) and slide on the securing clip (3).
Attach the door tting bracket (4) to the connecting arm (1) using
the short bolt (5) and slide on the securing clip (3).
Pull once on the emergency release wire (N). The trolley (1)
is disengaged. Tighten screw (8) on the lintel tting.
Push the trolley (1) with the connecting arm (2) as far forward
as possible (3). If necessary, release the switch trigger (4).
Align the door tting bracket (5) to the door centre mark (VM)
and mark 5 drill holes. Drill 5 holes (Ø 5 mm).
Insert hexagon-head screws (6) and tighten securely.
Release the switch trigger (4) and push right up to the trolley (7).
Tighten the switch trigger (4) screw securely.
4
N
1
2
6
4
3
21
5
BACK
HINTEN
NOTE!
Trim (e.g. saw off and debur) the projecting part of the ceiling
bracket (4).
Release the rear switch trigger (1) and push all the way to the back
until the stop (2). Open the door (3) manually.
Push the switch trigger (1) right up to the trolley (5). Securely tighten
the screw on the switch trigger (1).
17
18
18
19
20
20
21