Operation Manual
Installation
11
Installation
CAUTION!
Use a non-slip, stable stepladder!
THP
THP
11
5–65 mm
min. 35 mm
THPTHP
11
5–65 mm
min. 35 mm
11
max. 30°
FRONT
VORNE
NOTE!
If the distance between the ceiling and the lower edge of the
C-rail is greater than 245 mm, then extend the suspension
bracket (with perforated steel strip).
NOTE!
Please note that this distance might be smaller, if the door
handle is located at the centre of the door. Ensure that the
door movement is not obstructed.
Determine the door´s highest up-position (THP):
Open the door and measure the smallest clearance (min. 35 mm)
between the top edge of the door and the ceiling. The distance between
THP and the lower edge of the C-rail must be between minimum 5 mm
and maximum 65 mm, whereby the push rod must be at an angle
of max. 30°!
12
S
30
min.15
30
15
15
D
½
½
½
½
VMVM
13
NOTE!
For installation on the ceiling (D), drill holes at distances of
15 mm, if possible. Smaller angle of inclination of the xing
brackets.
The drive mechanism can be mounted on lintel (S) or ceiling (D).
Measure front centre point (VM) of door and mark on door and on lintel
or ceiling.
15
½
½
½
½
HMHM
15
VM
74 mm 74 mm
10 mm
65 mm
14
THP
Make a mark 74 mm to right and left of centre of door (VM) at same
height on lintel or ceiling (see g. 12). Drill two holes (Ø 10 x 65 mm
deep).
NOTE!
When safety goggles when drilling!
Check thickness of ceiling, particularly in the case
of prefabricated garages!
Open door. Transfer door centre mark (HM) on to the ceiling.
Close door.
NOTE!
Protect control housing (6) from damage!
16
2
6
4
5
31
FRONT
VORNE
Insert plug (1). Life up drive mechanism (2) at the front. Secure lintel
tting (3) at front with two screws (4) and plain washers (5).
11
12
13
14
15
16