Installation Instructions

73
46900V001_Rev-D_EN
Problem Possible cause Test/check Remedy
Operator stops the
door during closing
and opens it partially
or completely.
Door has detected an
obstacle
Check whether there are
any objects in the movement
range of the door.
Remove the object
If necessary, have door
mechanism checked and set by a
qualiedspecialist
Photocell was
interrupted
Check LEDs on photocell. Remove obstacle
Photocell defective or
misaligned
Align photocell
Check wiring
If necessary, have defective
photocell replaced
Operator stops while
the door is opening.
Door has detected an
obstacle
Check whether there are
any objects in the movement
range of the door.
Check the weight balance
of the door - it must run
smoothly.
Remove obstacle
If necessary, have door
mechanism checked and repaired
byaqualiedspecialist
Lighting on the
operator or the
Lumi+ supplemental
lighting does not
work
Operator lighting
defective
Lumi+ supplemental
lighting defective
Have motor carriage replaced with
anewonebyaqualiedspecialist
Ifnecessary,retrotLumi+
supplementary lighting
Speed varies while
opening and closing
the door
Track dirty Clean with a moist lint-free cloth
See Chapter "15.3 Care"
Chain tightened
incorrectly
Tighten the chain, see Chapter
"6.3 Installation of the operator
system"
16. Troubleshooting
16.5 Replacing the motor carriage
The instructions for "Disassembling the motor
carriage" can be downloaded from SOMMER at:
www.sommer.eu
If applicable, save the existing settings on the available
motor carriage via SOMlink and a WiFi-enabled device.
The settings can be transferred to the new motor
carriage later.
The new motor carriage is in delivery condition from the
factory. After replacing the motor carriage, make sure that
used accessories have been transferred to the new motor
carriage.
Commissioning must be repeated and the special
functions of the motor carriage must be reset, see
Chapter "9. Commissioning" and "10. Connections
and special functions of the motor carriage".
Handheld transmitters which are used must also be
reprogrammed, see Chapter "10.5 Programming the
transmitter". On the other hand, the transmitter does not
have to be programmed if the Memo accessory part has
already been used.
After successful commissioning, carry out a final test and
a function test, see Chapter "13. Function test and final
test".
INFORMATION
Save the existing settings of the motor
carriage with the help of SOMlink and a
WiFi-enabled device. After the new motor
carriage has been inserted, reinstall the
data.