Installation Instructions

58
46900V001_Rev-D_EN
12. twin operation
9. Programme the handheld transmitters for the
respective operators, see Chapter "10.4 Explanation
of the radio channels" and "10.5 Programming the
transmitter".
INFORMATION
Only one handheld transmitter can
be assigned per function. Undesired
malfunctions could otherwise occur.
12.4 Partial opening
One partial opening can be programmed for each of
the two operators (master and slave). Programming or
deletion is performed as for the standard equipment,
see Chapter "10.17 Setting partial opening" and
"10.18 Deleting partial opening".
Example:
Master on radio channel CH 2 (partial opening) on
handheld transmitter button 3. For the slave, on radio
channel CH 2 (partial opening) on handheld transmitter
button 4.
Wired
The COM input and signal on the ceiling control unit can
be used for this purpose. DIP switch 4 on the ceiling
control unit must be ON.
The input is then no longer available for connection of a
photocell.
Mode of operation
If button 2 (partial opening) is activated, the master
receives the partial opening command. See also chapter
"10.17 Setting partial opening".
12.5 Defined opening and closing
The functions Defined opening and closing of the
operators (master and slave) can only be configured via
the CH 3 and CH 4 radio channels. These settings are
not available when corded or via the Conex accessory
part.
12.6 Door status display
If DIP switch 2 on the ceiling control unit is set to ON,
the relay is activated during door movement and when
the door is open. It remains activated until both operators
(master and slave) are again at the door CLOSE end
position.
12.7 Lighting for twin operation
The lighting can be switched on and off for the selected
operator via the respective handheld transmitter. This
also applies for the connected supplemental lighting, see
also Chapter "10.16 Setting the lighting function".
12.8 Photocell
Optionally, a photocell can be connected. The photocell
must be configured in such a way that it can be aligned
to cover two doors. If the photocell is interrupted, the
operator of the moving door reverses. See also chapter
"11.6 Photocell and frame photocell".
INFORMATION
If a photocell is retroî‚¿tted on a
programmed system, the control unit must
be reset, see Chapter "10.13 Resetting the
control unit."
12.9 External button
With the Conex additional circuit board, both operators
(master and slave) can be operated in pulse sequence
mode. Fit the Conex as described in the separate
instructions. Set DIP switch 1 on the ceiling control unit
to ON.
Mode of operation
Button 1 - master
Button 2 - slave
12.10 Reset
The slave becomes the master again when a factory
reset is carried out. The operator must be configured as
the slave again via SOMlink and a WiFi-enabled device,
see Chapter "12.3 Selecting and configuring master
and slave".